200 Series - Single Hung Welded Sash

Structural Performance
Cam Lock w/Keeper 211 Meeting Rail
Grade R-50
Test No. 90-201
Test Date 1/15/90
Test Specification AAMA 101 V-86
Size 3' 8" x 5' 1/8" (44" x 60 1/8")
Reinforcemant 211 Meeting Rail Only
Air Infiltration @ 15 MPH .11 CFM/ft.
Air Infiltration @ 25 MPH .18 CFM/ft.
Water Resistance 7.5 psf
Structural Performance 75 psf
Thermal Performance
Test No. ATI-4001
Test Date 12/17/86
Test Specification AAMA 1502.7-81
ASTM C236-80
AAMA 1503.1-80
Size 3' 8" x 5' 1/8" (44" x 60 1/8")
Glazing DSB, Enviroshield TM, Air Filled Swiggle Spacer
CRF 72
Air Infiltration @ 15 MPH .03
U Value .30
R Factor 3.33
NFRC Simulations
Test No. ETC-93-034-537-3
Test Date 8/25/93 Revised 9/29/93
Size Glazing U Value R Factor
36" x 60" DSB, Clear Annealed, Air Filled Swiggle Spacer .49 2.04
48" x 72" DSB, Clear Annealed, Air Filled Swiggle Spacer .50 2.00
36" x 60" DSB, Enviroshield TM, Air Filled Swiggle Seal Spacer .30 3.33
48" x 72" DSB, Enviroshield TM, Air Filled Swiggle Seal Spacer .30 3.33
Sound Transmission Loss
Test No. 482043
Test Date 12/1/87
Specification ASTM E90-85
Size 36" x 48"
Glazing Sound Transmission Class (STC)
Double Strength x Double Strength 32
Double Strength x 1/4" Laminated 36
1/4" Laminated x 1/4" Laminated 36

close window / print page